Objectives: Determine the prevalence and risk factor of neonatal hearing loss in the high-risk group

Material and Method: A prospective descriptive study, using the criteria of “high-risk” as defined by the Joint
Committee of Infant Hearing 1994, American Academy of Pediatrics, 465 newborn in Songklanagarind Hospital
were screened with portable otoacoustic emissions (OAEs) before being discharged between July 1st, 2004
and December 31st, 2006. Based on the examinations, the results were divided into two groups, “pass” and
“refer”. The neonates who failed the screening test were referred for further checks with conventional OAEs
and if they failed again, then the authors reassessed them with auditory brainstem responses (ABR).

Results: Four hundred fifty eight infants (98.5%) in the high-risk group passed the primary screen for both
ears. One infant (0.21%) was confirmed with unilateral sensorineural hearing loss and three infants (0.64%)
were confirmed with bilateral hearing impairment above 30 dB. Three infants (0.64%) were lost to follow up.
High-risk factors of hearing loss in the present study included 226 infants from premature birth (48.6%), 159
infants exposed to ototoxic medications (34.2%), and 61 infants with respiratory distress syndrome that
required mechanical ventilation for at least five days (13.1%).

Conclusion: Otoacoustic emissions are a very quick and noninvasive technique, and suitable for hearing
screening in infants.