Views: 1,315 | Downloads:
245
| Responses: 0
XML | Respond to this article | Alert & updates | Request permissions | Email to a friend |
Original ArticleOpen Access
Detection of Inducible Clindamycin Resistance in Staphylococci by Disk Diffusion Induction Test
Objective: To detect inducible clindamycin (CL) resistance in staphylococci by disk diffusion induction test
(D-test).
Material and Method: One thousand one hundred eighty clinical isolates of staphylococci were tested for
inducible CL resistance by placing erythromycin (E) disk and clindamycin disk 12 mm apart (edge to edge)
on Mueller-Hinton agar plate inoculated with staphylococci. The flattening of CL zone (D-shaped zone) near
E disk indicated an inducible CL resistance was observed after 18-24 h of incubation.
Results: Inducible CL resistance was detected in 9.9% of staphylococci isolates. It was found in methicillinresistant
Staphylococcus aureus (MRSA) more than methicillin-sensitive Staphylococcus aureus (MSSA) and
coagulase-negative staphylococci (CoNS) 35.9%, 4.7%, and 5.5%, respectively.
Conclusion: To avoid misinterpretation of CL result, D-test is recommended for routine detecting of inducible
CL resistance in staphylococci. It provides the confident laboratory report of CL as resistant (D-shaped zone
positive) or as susceptible (D-shaped zone negative) particular for E resistant isolates.
Keywords: Clindamycin, Drug resistance, D-test, Methicillin-resistant Staphylococcus aureus, Microbial
sensitivity tests, Staphylococcus aureus
(D-test).
Material and Method: One thousand one hundred eighty clinical isolates of staphylococci were tested for
inducible CL resistance by placing erythromycin (E) disk and clindamycin disk 12 mm apart (edge to edge)
on Mueller-Hinton agar plate inoculated with staphylococci. The flattening of CL zone (D-shaped zone) near
E disk indicated an inducible CL resistance was observed after 18-24 h of incubation.
Results: Inducible CL resistance was detected in 9.9% of staphylococci isolates. It was found in methicillinresistant
Staphylococcus aureus (MRSA) more than methicillin-sensitive Staphylococcus aureus (MSSA) and
coagulase-negative staphylococci (CoNS) 35.9%, 4.7%, and 5.5%, respectively.
Conclusion: To avoid misinterpretation of CL result, D-test is recommended for routine detecting of inducible
CL resistance in staphylococci. It provides the confident laboratory report of CL as resistant (D-shaped zone
positive) or as susceptible (D-shaped zone negative) particular for E resistant isolates.
Keywords: Clindamycin, Drug resistance, D-test, Methicillin-resistant Staphylococcus aureus, Microbial
sensitivity tests, Staphylococcus aureus
Download:
PDF