Submit manuscript

Fractional Thigh Volume by Three-Dimensional Ultrasonography for Birth Weight Prediction

Nattinee Srisantiroj MD*, Pharuhas Chanprapaph MD*, Chulalak Komoltri Dr PH**

Affiliation : * Division of Maternal -Fetal Medicine, Department of Obstetrics and Gynecology, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand ** Division of Research Development, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand

Objective : To determine the correlation between actual birthweight (BW) and fetal weight calculated from fractional thigh volume (ThiV). Material and Method: The authors have conducted a prospective, cross-sectional study of normal Thai fetal thigh volume. There were 176 eligible pregnant women who met the criteria of singleton with no fetal anomaly were recruited into the present study. Prior to the present study, 3 operators had been trained and standardized for fractional ThiV measurement by an expert for the first 20 cases. To generate the fetal weight calculating formula, fetal ThiV data from the first 100 cases were employed. Then, the authors’ new prediction formula was compared and validated with the Hadlock’s and the Tongsong’s formula in 56 normal late-third- trimester fetuses. All patients were assessed for 2D fetal biometry and 3D fractional ThiV within one week before delivery.
Results : A total of 176 fetuses underwent ultrasound at the gestational age of 38.5 + 2.1 weeks. The reproducibility of fractional ThiV measurement technique showned very good correlation in both inter- and intra-observer reliability as observed by the high intraclass correlation (0.971-0.994). By using the regression model, fractional ThiV presents a superior correlation to actual BW (r = 0.965). The fitting formula is characterized by predicted fetal BW (g) = 774.744 + 32.658 x fractional ThiV (ml). The presented new formula shows the smallest absolute percentage error (APE) for BW estimation when compared to that of Hadlock’s and Tongsong’s.
Conclusion : Fetal 3D-fractional ThiV is consistent with actual BW. The measurement of fractional ThiV can improve the accuracy of fetal weight prediction especially in some eventful conditions.

Keywords : Three-dimensional ultrasound, Two-dimensional ultrasound, Birth weight prediction


All Articles Download


INFORMATION

Contact info

JOURNAL OF THE MEDICAL ASSOCIATION OF THAILAND
4th Floor, Royal Golden Jubilee Building,
2 Soi Soonvijai, New Petchburi road,
Bangkok 10310, Thailand.
Phone: 0-2716-6102, 0-2716-6962
Fax: 0-2314-6305
Email: editor@jmatonline.com

JMed Assoc Thai
MEDICAL ASSOCIATION OF THAILAND
ISSN: 0125-2208 (Print),
ISSN: 2408-1981 (Online)
The content of this site is intended for health professionals.

Submissions

» Online Submissions » Author Guidelines » Copyright Notice » Privacy Statement

Other

» Journal Sponsorship » Site Map » About this Publishing System

© MEDICAL ASSOCIATION OF THAILAND. All Rights Reserved. The content of this site is intended for health professionals.