Impact of Septic Shock Hemodynamic Resuscitation Guidelines on Rapid Early Volume Replacement and Reduced M

Chairat Permpikul MD*, Surat Tongyoo MD*, Ranistha Ratanarat MD*, Warakarn Wilachone MD*, Aekarin Poompichet MD*

Affiliation : * Division of Critical Care, Department of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand

Background : Septic shock is one of the most serious conditions associated with high mortality. We recently developed a modified septic shock management guideline focusing on rapid restoration of hemodynamics by using clinical endpoint. Our aim was to analyze patients’ outcomes following the guideline implementation. Material and Method: A retrospective review of hemodynamic data sheet and clinical outcomes of patients admitted to medical ICU and medical Wards and during June 2004 and February 2006.
Results : One hundred and four patients’ records were retrieved. The patients’ mean age was 62.5 + 18.6 year. Their mean APACHE II score were 24.9 + 6.7 and the overall mortality was 59%. Sixty eight patients (65.4%) underwent guideline directed therapy (guideline group). The guideline group received higher volume resus- citation from the first hour of resuscitation (1,016.3 + 675.0 ml vs. 521.4 + 359.2 ml, p < 0.001) to the forty eighth hour (10,096.9 + 3,256.1 ml vs. 8,067.3 + 2,591.9 ml, p = 0.006). More of them achieved the therapeu- tic goal within 6 hours (86.8% vs. 44.4%, p < 0.001) and their hospital mortality was lower (41.2% vs. 69.4%, p = 0.008). When analyzing differences between those who survived and those who died, more of the surviving patients underwent guideline directed treatment (79.5% vs. 55%, p = 0.012). They received higher volume replacement from the first hour to the end of the twelfth hour (first hour 1,098.0 + 723.0 vs. 660.9 + 478.9 ml, p < 0.001; the end of the twelfth hour 3,746.6 + 1,799 vs. 3,014.1 + 1,579.9 ml, p = 0.038) and more of them achieved the therapeutic goal within 6 hours (95.5% vs. 55%, p < 0.001). Multivariate analysis of factors associated with mortality disclosed APACHE II score, volume resuscitation more than 800 ml in the first hour and achievement of the therapeutic goal within 6 hours.
Conclusion : Implementation of our modified septic shock guideline is associated with rapid initial volume replacement, prompt achievement of therapeutic goal and improved outcomes. Volume resuscitation greater than 800 ml in the first hour is associated with better survival.

Keywords : Septic shock, Hemodynamic guideline, Fluid therapy


All Articles Download


INFORMATION

Contact info

JOURNAL OF THE MEDICAL ASSOCIATION OF THAILAND
4th Floor, Royal Golden Jubilee Building,
2 Soi Soonvijai, New Petchburi road,
Bangkok 10310, Thailand.
Phone: 0-2716-6102, 0-2716-6962
Fax: 0-2314-6305
Email: editor@jmatonline.com

JMed Assoc Thai
MEDICAL ASSOCIATION OF THAILAND
ISSN: 0125-2208 (Print),
ISSN: 2408-1981 (Online)
The content of this site is intended for health professionals.

Submissions

» Online Submissions » Author Guidelines » Copyright Notice » Privacy Statement

Other

» Journal Sponsorship » Site Map » About this Publishing System

© MEDICAL ASSOCIATION OF THAILAND. All Rights Reserved. The content of this site is intended for health professionals.